Model S400
Specifications
Ordering Information
   
Applications:
In-Line & Submersion

Maximum Flow Rate:
10 ft (3 m) per second

Output Impedance:
< 250 megohms at 25°C

Chemical-Resistant Wetted Materials
These high quality sensors are constructed of corrosion-resistant wetted materials including Ryton®, Teflon® and glass.

Coaxial Porous Teflon® Reference Junction
The large annular junction resists fouling. Additionally, the sealed, double-junction reference electrode is highly resistant to poisoning.

Options Include:
  • Built-in temperature compensation
  • Built-in solution ground
  • Custom cable lengths
  • Choice of cable connectors

SPECIFICATIONS

pH Range

0–14 pH Range

ORP Range

± 5000 mV

Temp Range

0–105ºC

Max Pressure/Temp

150 psig at 100ºC

Reference

Ag/AgCl

Wetted Materials

Ryton, Teflon and Glass

Standard cable length

10 feet

Model S400


Before you call to place your order, please print out this page and fill in this PART# BOX by selecting from options below. Boxes 1-10 must be filled in.

Part #
1
2
3
4
5
6
7
8
9 10 11 12
S-4
0
0
 
T
 
 
 
         
OPTIONS Check options 1-10 below to complete PART# BOX above.
1 — 2 Body Style
[00] Standard Insertion, Guarded Bulb, 3/4" NPT. Not available w/Flat Bulb or Recessed Junction.
3 — Body Material
  [R] Ryton®
[G] Grounded *(see note below)
4 — Liquid Junction:
[T] Coaxial Teflon®
5 — 6 Measurement Electrode:
[33] pH, HT-3 Rugged Dome Bulb
[43] pH, HT-4 High pH Bulb (for pH 13 and above)
[PB] ORP, Platinum Band
7 — Temperature Compensator:
[0] T.C. not required
[1] 3K Ohms, used on older models of TBI/Bailey & Uniloc transmitters
[9] 301 Ohms for use with older Great Lakes models, such as 60, 70, 90, 570 and 690
[D] Pt 100 Ohms for Rosemount (Uniloc) Model 1054, Beckman SoluComp, TBI/Bailey TB82 & TB84, Foxboro Models 870 & 874, Yokogawa and many European models
[H] Pt 1000 Ohms for Yokogawa, Conducta, Polymetron and many European models
8 — Cable Type:
[A] 3 mm Low Noise Coax, for pH without built-in TC, or for ORP
[M] 5 mm Low Noise Coax, for pH without built-in TC, or for ORP
[E] Jacketed Coax w/ TC leads
[N] Jacketed Coax w/ TC and solution ground leads
9 — 10 Cable Length:
[10] 10 ft - standard length
[XX] Specify length (in feet) if other than standard (see above for price adder per foot)
11 — 12 Sensor Connectors:
[BC] BNC only (for use with ORP electrodes or with sensors w/o TC or solution ground)
[FB] BNC for pH and Ferrules on all other leads (for use with Terminal Block or Terminal Strip)
[FF] All Ferrule connectors (for use with Terminal Block or Terminal Strip)